Quality Radar level transmitter supplier factory


Posted On Mar 31 2024

Top rated Radar level sensor provider: When the cover above the closed metal cover is opened, the false signal disappears, the overall noise line decreases, and the echo curve decreases. After analysis, it is determined that the closed metal cover is the main cause of false signals, the radar level meter antenna is made of plastic, and the radar waves emitted by the antenna leak into the external environment. The closed metal shield is used to cover the instrument, and the leaked radar wave signal is received by the antenna after several reflections inside the shield, generating a false level. Therefore, the metal shield was modified to a ring-shaped non-sealed shield at a later stage, and the radar level meter jump was significantly reduced. See extra information on radar level transmitter suppliers.

Working principle: Tube in the liquid level meter has a magnetic float, float design, according to the proportion of medium float magnet steel and container liquid level at the same level, wholesale liquid level gauge in a semiconductor magnetel liquid level gauge sensor LED display scale, and orderly arranged from top to bottom, and LED module corresponding to the magnetic field magnetic sensor, the magnetic semiconductor, triggering the corresponding digital circuit, liquid level above the red LED display, The LED below the liquid level gauge is displayed in green, the red in gas phase, and the green in liquid phase. The red-green junction is the actual liquid level in the container.

Measuring principle of radar water level meter: The radar level gauge adopts the working mode of transmitting-reflecting-receiving. The electromagnetic wave emitted by the antenna is reflected by the surface of the measured object and then received by the antenna. After measuring the distance from the water surface to the radar antenna, the elevation of the water surface can be calculated according to the elevation of the radar antenna. The radar water level meter adopts pulse wave technology with low power consumption. It can be powered by two-wire 24 VDC, 485 interface output, or can be directly powered by 12 VDC, SDI-12 interface output, with high accuracy and wider application range.

The performance of any level technology relative to instrument induced errors, calibration nuances, and vulnerabilities to process dynamics can have an immediate and adverse impact on fuel consumption. Seamless response to changes in demand and reducing maintenance associated with the instrumentation or damage to hardware are residual benefits that have their own financial ramifications; these aspects should also be considered when implementing any technology. In addition to the “open” or deaerating feedwater heater, the more common shell and tube heat exchangers/condensers can be found in larger scale steam generation cycles where their costs are offset by gains in thermal efficiency. The effectiveness of a shell and tube heat exchanger in transferring energy is contingent, barring hardware anomalies, on accurate level control.

Secondly, in cement production, material level measurement encountered another difficulty is strong dust interference, especially pneumatic conveying powder silo, dust flying when feeding, low visibility, laser level meter and high energy ultrasonic level meter can not be measured, although radar level meter at this time can receive part of the surface echo. But the echo signal was also weakened. In addition, due to the uneven surface of the radar echo is refracted, will also lead to the existence of radar echo; In addition, there are some conditions from the bottom to the bin inflation, so that the material surface loose, material level measurement is more difficult.

With emphasis placed on customer satisfaction, innovation, product development and overall business transformation, the company continued to innovate and expand with each passing year. KAIDI has successfully achieved global recognition, obtaining the leading position as Asia’s top process automation sensor manufacturer. In the past 5 years, the company has undergone tremendous growth and development – flourishing internationally and providing customers worldwide with the best customized solutions for process automation. Read more info at kaidi86.com. Kaidi Energy is a level gauge manufacturer which more than 20 years of industrial automation experience.

In the measurement circuit of the radar level gauge, when there is additional DC current and voltage, it is DC interference. In severe cases, the measuring instrument will not work properly. The sources of DC interference are as follows: AC interference can be divided into line-to-line interference and ground interference. Inter-line interference refers to the AC voltage between the output ends of the radar level gauge (compensation line) under external influence. This interference is also known as lateral, common mode or common mode interference. Generally speaking, the line-to-line interference voltage can reach several millivolts or even tens of millivolts.

For the continuous measurement of corrosive, high viscosity, flammable and toxic liquids, liquid-liquid interface and solid-liquid interface that are difficult to measure by ordinary liquid level meter , ultrasonic level meter should be selected, but should not be used in occasions with large liquid level fluctuations . Ultrasonic level meter are suitable for measuring media that can fully reflect and transmit sound waves, but should not be used in vacuum. The ultrasonic flow meter should not be used in process equipment where internal obstacles affect the propagation of sound waves.

Advanced Radar Level Measurement: The constant progress of innovation continues to push the limits of radar level measurement, propelling this technology into areas of capability and pertinence. As industries undergo transformations and integrate the Industrial Internet of Things (IIoT) into their operational processes radar devices have evolved to meet these changing demands. Integration with IIoT- Leading the Way to Industry 4.0 One of the transformative developments in radar level measurement is the seamless integration of Industrial Internet of Things (IIoT) capabilities into radar devices. These radar sensors equipped with IIoT features have become important components in Industry 4.0 initiatives ushering in an era where data driven excellence prevails in operations.

Application conditions, application conditions generally include calm liquid level, slightly fluctuating surface, turbulent surface, with stirring, with foam and so on. The more complex the conditions, the more interference echoes, and the smaller the actual measured range. In a complex environment, a precision radar with strong ability to deal with interference echoes or an antenna with a larger size should be selected.

Last Updated on: April 19th, 2024 at 9:39 am, by


Written by Petrescu Dan