Local exhaust ventilation LEV testing guide


Posted On Oct 28 2019

There could be a number of possible reasons why the booth was not being used correctly. Perhaps management and the workforce don’t fully understand the health risks and so don’t appreciate the importance of using the controls properly. Perhaps the workers haven’t been properly trained on how to use the booth. However, there could be a problem with the design of the booth. It is possible that carrying out the work inside the enclosure presents the operator with some practical difficulties. Perhaps the fine work required is difficult to complete properly if the casting is inside the booth or the booth dimensions, particularly the height, could cause the worker to adopt an awkward posture which causes discomfort and could lead to musculoskeletal problems. Solving one problem often creates another. Ergonomics is often neglected when designing engineering controls for chemical hazards. Ideally workers need to be consulted and involved in the specification and design of the controls and its good practice to build and test a prototype before finalising the design. Proper commissioning of the controls should also check for usability.

What does LEV testing involve? A thorough examination of equipment including hoods, filters and ducts, measurement of the technical performance using the appropriate equipment and assessment of the effectiveness of the LEV system. We will make recommendations should your system not be up to the required standard. All work is carried out according to HSE guidance which governs LEV testing.

According to the HSE, around 13,000 workers in the UK die each year from historic work-related exposure to airborne contaminants at work leading to lung disease and various cancers. These figures are estimated to be attributed to past exposure, primarily to chemical and dust at work.

How Welding Supplies Direct can help ? WE will carry out a thorough tests in line with COSHH Regulation 9 as detailed in HSE Guide HSG258 Our levels of service can be tailored to your Companies needs. However, most clients choose to take advantage of by combining servicing with the LEV testing. See more info on Local Exhaust Ventilation LEV Testing.

The employer must consider other control options and use them where appropriate (see HSE leaflets Working with substances hazardous to health1 and Clearing the air2) before applying LEV. In some circumstances, LEV may not be a reasonably practicable control as there may be many sources or extensive contaminant clouds that are too large for LEV alone to control. LEV suppliers provide goods (an LEV system) and may then act as a service provider. Designers interpret the requirements of the employer and advise on an effective LEV system which is capable of delivering the required control.

Last Updated on: November 2nd, 2019 at 9:38 am, by


Written by Petrescu Dan